{"product_id":"eizo-radiforce-mx217-2mp-dicom-medical-monitor","title":"EIZO RadiForce MX217 21.3-inch 2MP DICOM Medical Monitor","description":"\u003cstyle\u003e.mm-detail{text-align:left}.mm-detail section{scroll-margin-top:100px}.mm-detail .mm-columns,.mm-detail .mm-cards{display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,260px),1fr));gap:28px}.mm-detail article{background:#f3f7fa;border:1px solid #dce6ed;border-radius:5px;padding:22px}.mm-detail details{padding:16px 0;border-bottom:1px solid #dce6ed}.mm-detail summary{font-weight:600;cursor:pointer}.mm-detail .mm-kicker{font-size:11px;letter-spacing:1px;color:#115b92;font-weight:700}\u003c\/style\u003e\u003cdiv class=\"mm-detail tc-editorial\"\u003e\n\u003csection id=\"monitor-overview\"\u003e\u003cdiv class=\"mm-columns\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"mm-kicker\"\u003eEIZO RADIFORCE MX217 · 2MP MEDICAL DISPLAY\u003c\/p\u003e\n\u003ch2\u003eA compact medical display for patient charts and image review.\u003c\/h2\u003e\n\u003cp\u003eThe EIZO RadiForce MX217 is a 21.3-inch 2MP-class color medical monitor with DICOM Part 14 calibration. Its portrait-format 1200 × 1600 panel supports patient-chart display and radiological image review in hospitals and clinics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003ePlan your reading workstation\u003c\/h3\u003e\n\u003cp\u003eSpecify the exact regional model and operating luminance before deployment. European MX217-HB and MX217-SB configurations have separate specifications; their calibration values are not assumed for this base-model listing.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/eizo-medical-displays-catalog\"\u003eCompare EIZO Medical Displays\u003c\/a\u003e · \u003ca href=\"\/collections\/worklist-monitors\"\u003eChoose a Worklist Monitor\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"monitor-features\"\u003e\u003ch2\u003eMX217 features for your imaging workflow\u003c\/h2\u003e\n\u003cdiv class=\"mm-cards\"\u003e\n\u003carticle\u003e\u003ch3\u003eIntegrated DICOM calibration\u003c\/h3\u003e\n\u003cp\u003eRadiCS LE and the Integrated Front Sensor support calibration without repeatedly mounting an external sensor. Brightness stabilization and Digital Uniformity Equalizer help manage screen consistency.\u003c\/p\u003e\u003c\/article\u003e\u003carticle\u003e\u003ch3\u003eGrayscale and color together\u003c\/h3\u003e\n\u003cp\u003eHybrid Gamma PXL handles mixed image content at pixel level. The color IPS panel has a typical brightness of 500 cd\/m² and an 1800:1 typical contrast ratio.\u003c\/p\u003e\u003c\/article\u003e\u003carticle\u003e\u003ch3\u003ePortrait or landscape workflow\u003c\/h3\u003e\n\u003cp\u003eImage Rotation Plus links RadiCS LE with the gravity sensor to adjust image orientation. DisplayPort output supports compatible daisy-chain arrangements.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"monitor-specifications\"\u003e\u003ch2\u003eEIZO RadiForce MX217 technical specifications\u003c\/h2\u003e\n\u003cdiv class=\"mm-columns\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eDisplay \u0026amp; calibration\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer \/ model\u003c\/th\u003e\n\u003ctd\u003eEIZO RadiForce MX217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScreen \/ panel\u003c\/th\u003e\n\u003ctd\u003e21.3-inch color IPS; LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNative resolution\u003c\/th\u003e\n\u003ctd\u003e1200 × 1600; 2MP class; 3:4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTypical brightness\u003c\/th\u003e\n\u003ctd\u003e500 cd\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended calibration\u003c\/th\u003e\n\u003ctd\u003eNot verified for base model; confirm supplied configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTypical contrast \/ pixel pitch\u003c\/th\u003e\n\u003ctd\u003e1800:1; 0.270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDICOM \/ uniformity\u003c\/th\u003e\n\u003ctd\u003eDICOM Part 14; Digital Uniformity Equalizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration sensor\u003c\/th\u003e\n\u003ctd\u003eIntegrated Front Sensor (IFS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eConnections \u0026amp; installation\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVideo inputs\u003c\/th\u003e\n\u003ctd\u003e1 × DisplayPort; 1 × DVI-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVideo output\u003c\/th\u003e\n\u003ctd\u003eDisplayPort daisy chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB hub\u003c\/th\u003e\n\u003ctd\u003e1 × Type-B upstream; 2 × Type-A downstream (USB 2.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVESA mounting\u003c\/th\u003e\n\u003ctd\u003e100 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input \/ typical use\u003c\/th\u003e\n\u003ctd\u003e100–240V AC, 50\/60Hz; 23W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet monitor weight\u003c\/th\u003e\n\u003ctd\u003e7.2 kg with stand; not packaged shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"monitor-application\"\u003e\u003cdiv class=\"mm-columns\"\u003e\n\u003cdiv\u003e\n\u003ch2\u003eApplications \u0026amp; clinical scope\u003c\/h2\u003e\n\u003cp\u003eFDA 510(k) K230684 covers radiological image review, analysis and diagnosis by trained medical practitioners. Mammography is excluded; this listing does not claim diagnostic mammography or DBT use.\u003c\/p\u003e\n\u003cp\u003eThe EIZO US specification lists 500 cd\/m² typical brightness but does not state a recommended calibration target. Confirm that target with EIZO for the supplied configuration; do not substitute MX217-HB or MX217-SB values. No HDMI or USB-C video input is listed.\u003c\/p\u003e\n\u003cp\u003eVerify PACS compatibility, native-resolution output, reading-room conditions and facility QC requirements before deployment.\u003c\/p\u003e\n\u003ch3\u003eOne monitor \u0026amp; standard accessories\u003c\/h3\u003e\n\u003cp\u003eEIZO lists one DisplayPort cable, one USB Type-A–Type-B cable, an AC power cord, RadiCS LE and documentation with its standard kit. Contents vary by country and supplied unit; the written quote confirms the actual kit. No workstation, dictation microphone or secondary monitor is included.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eProduct \u0026amp; purchasing details\u003c\/h3\u003e\n\u003cp\u003eOne MX217 monitor. Condition, availability, price and shipping are confirmed in your quote. Contact Texel Comp for technical support options.\u003c\/p\u003e\n\u003cp\u003eEIZO lists a standard five-year manufacturer warranty. Confirm the quoted unit's eligibility, remaining coverage and applicable LCD brightness or operating-hour limits before ordering; country and configuration terms can differ.\u003c\/p\u003e\n\u003cp\u003eSend your quantity, workstation, graphics outputs and delivery ZIP code. Installation, full RadiCS, RadiNET Pro and external QC sensors are separate quote items.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote\"\u003eRequest an EIZO MX217 quote\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"monitor-faq\"\u003e\u003ch2\u003eMX217 buying \u0026amp; setup questions\u003c\/h2\u003e\n\u003cdiv class=\"mm-columns\"\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the MX217's FDA clinical scope?\u003c\/summary\u003e\u003cp\u003eFDA 510(k) K230684 covers radiological image review, analysis and diagnosis by trained practitioners and excludes mammography. Suitability also depends on the facility's modality and QC requirements.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes MX217 have an Integrated Front Sensor?\u003c\/summary\u003e\u003cp\u003eYes. EIZO lists an Integrated Front Sensor, backlight sensor and ambient light sensor. The front sensor works with RadiCS LE for supported DICOM calibration.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs 500 cd\/m² its recommended calibration target?\u003c\/summary\u003e\u003cp\u003e500 cd\/m² is the typical brightness listed on the US product page. A recommended target for the quoted base configuration has not been verified; confirm it before installation.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs MX217 the same configuration as MX217-HB or MX217-SB?\u003c\/summary\u003e\u003cp\u003eDo not assume that. Regional suffixes can identify different luminance configurations and specifications. Your quote should identify the exact supplied model and calibration requirements.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"monitor-resources\"\u003e\u003ch3\u003eManufacturer \u0026amp; regulatory resources\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.eizo.com\/products\/radiforce\/mx217\/\"\u003eEIZO MX217 specifications, manuals \u0026amp; downloads\u003c\/a\u003e · \u003ca href=\"https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf23\/K230684.pdf\"\u003eFDA K230684 clinical indications\u003c\/a\u003e · \u003ca href=\"https:\/\/www.eizo.com\/warranty\/radiforce\/\"\u003eEIZO US warranty terms\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/diagnostic-medical-monitors\"\u003eCompare Diagnostic Medical Monitors\u003c\/a\u003e · \u003ca href=\"\/collections\/medical-displays\"\u003eShop all Medical Displays\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"EIZO","offers":[{"title":"Default Title","offer_id":67584235110626,"sku":"EIZO-MX217","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/0462\/8962\/files\/texel-mx217-front-studio.png?v=1791094433","url":"https:\/\/shop.texelcomp.com\/products\/eizo-radiforce-mx217-2mp-dicom-medical-monitor","provider":"Texel Comp ","version":"1.0","type":"link"}